MEDICORE

IRIS-T

As the artificial intelligence self-quarantine system, IRIS-T System uses an infrared thermal imaging camera to prevent the spread of highly pathogenic infectious diseases such as COVID-19 or any pandemic. It uses the medial canthus on the left and right sides of a person’s face without any contact between the examiner and the patient. It is a device that predicts the temperature of the eardrum by artificial neural network learning and determines whether a person has a high fever. It is mainly used in airports and ports.


Advantages & Features

- Apply the results of clinical research conducted at the Korean Thermal Data Center based on international standards for the first time in Korea
- If the inner canthus is measured by artificial neural network learning, the tympanic membrane temperature is predicted.
- Apply temperature compensation algorithm that reflects changes in surrounding temperature at airports and ports.
- Automatic language recognition and voice support through passport/ID scan (support 12 languages)
- Automatic identification function for those who get high fever
- Voice guidance function
- Self-test is possible so that visitors can measure themselves, and the test will be completed within 1~2 seconds
(preventing the secondary infection of the examiner)
- Central Quarantine Monitoring System between devices (one person can control the entire system)
- Save and transmit measured information in the database
- Alarm function when a person with high fever appears (connected to central control system)

ISO/TR 13154, the international standard for target area and methods for screening people with high fever in the Korean Thermal Ddata Center designated by the National Agency for Technology and Standards A temperature standard for screening people with high fever was created in accordance with the measurement guidelines (based on the 2nd edition in 2017), and Medicore is a participating organization in the Korean Thermal Data Center. The equipment was developed by applying the temperature standard for screening people with high fever.

Clinical Applications

Hospitals, Emergency Room

Features

Product Components

1. IRIS-T Main Box : 1ea
2. Stand & Cable : 1ea
3. User Manual : 1ea
4. Power Cable : 1ea

Specification

1. Detector : Uncooled Micro-Bolometer
2. Temperature measurement range : 14.5 ~ 40 ℃
3. Automatic & manual focus : Both all available
4. Pixel Resolution : IR 640(H) x 480(V) / CMOS 2592(H) x 1944(V)
5. Focus range : 40cm ~ Infinity
6. Spatial Resolution(IFOV) : 1.13 mrad
7. NETD : 50mk
8. Operating Temperature : -10 ~ 65 ℃
9. Frame Rate : 30Hz
10. Electric power AC : 100 ~ 220V, 50/60Hz

Product